Complete Installation Guide
Entry Sensor Version s5b (lid with ceiling mount threads)
01 — In the Box
02 — Hardware
03 — Power
04 — Networking
05 — Entryway Guidelines
06 — Mounting Options
07 — Wall Mounting
08 — Ceiling Mounting Toggle Anchor - Hollow Ceiling
09 — Ceiling Mounting Threaded and Expansion Anchors - Solid Ceiling
10 — Top of Frame Mounting
11 — Bottom of Frame Mounting
12 — Glass/Metal Adhesive Mounting
01 - In the Box
Product
- Entry Sensor
- Legal Information Booklet
- Quick Start Guide
Wall Mount Kit
- Wall Bracket (temporarily installed on sensor)
- Hex Key (2mm)
- 2pcs #8 x 1.25in Rounded Head Screws
- 2pcs Toggler Multi-Surface Anchors
- Rubber Plug
02 - Hardware
Alternative Mounting (Available For Order)
- Ceiling Mount Kit
- Door Frame Mount Kit
- Glass/Metal Adhesive Mount Kit
Sensors
Depth Sensor utilizing Class 1 Eye Safe Infrared Lasers
Environmental Ratings
- Indoor Rated Only
- Temperature: 32 - 95 F (0 - 35 C) with minimum 3in (7.6cm) clearance above the sensor
- Relative humidity: 20% to 80% non condensing
Indicators
Multi-color status LED
Unit Weight
1.4lbs (0.59kg)
Certifications
Certified Class 1 Eye Safe Laser Device
- EN/IEC 60825-1 2014 (2007 USA)
FCC Part 15 Subpart B Class A
- Conducted Emissions (15.107)
- Radiated Emissions (15.109)
CE Certification
IEC 60950-1:2009 Product Safety
EN 55032:2012
EN 301 489-1
RCM Mark (Australia & New Zealand)
RoHS2 Compliant
COO (country of origin): US
HS Code: 8471.90.0000
ECCN: EAR99
Dimensions and Features
- Enclosure Material: Anodized Aluminum
- Window Material: IR PMMA Plastic
- Removable Mount Arm
- 1/4in-20 threads for ceiling mounting
Interface
1x 10/100/1000 Base-T RJ45 interface
- 1x USB 2.0 Port for WiFi/Bluetooth dongle
- Reset Button
Labels
Serial Label: Appears on the sensor as shown.
MAC address: Can be found on the side of the box that the sensor came in.
Resetting the Sensor
To power reset the sensor to default factory settings, use the provided hex key or similar thin object to press and hold the reset button until the LED stops blinking (approx 10 seconds). The sensor must be plugged in and connected to power in order to reset.
Sensor LED Status Indicator
The sensor has an indicator LED located on the front of the sensor. The color chart to the right explains the meaning of each color, defines any issues, and lists what actions to take if necessary.
If the recommended action does not resolve the LED light error status, factory reset the sensor. To reset, press and hold the reset button on the back of the sensor until the LED light starts flashing white. If the issue persists, please reach out to support@density.io
03 - Power
Power Requirements
Density sensors require 802.3at PoE+ (Power over Ethernet) and need a constant 30W power budget.
Cabling Requirements
The sensor requires a Cat 5e or later ethernet cable (not included).
Option 1 - PoE+ Switch
Connect one end of a Cat 5e or later ethernet cable to a 802.3at (PoE+ Type 2) compliant network switch capable of providing 30W per port. Plug the other end of the ethernet cable into the sensor.
Each sensor requires 30W at the PSE (Power Supply Equipment / Switch) per 802.3at PoE+ Type 2 spec. Please ensure your switch is not overloaded or the sensor will fail to operate. (For example, if you have a 24-port 500W switch you can support up to 16 sensors at a time assuming no other load on the remaining ports).
Option 2 - PoE+ Injector Using WiFi
Plug the 30W PoE+ Injector into any standard wall outlet. Plug one end of a Cat 5e or later ethernet cable into the Data & Power Out port located on the bottom of the injector. Plug the other end of the ethernet cable into the sensor. Use the Unit Setup App to connect the sensor to a WiFi network.
Option 3 - PoE+ Injector Using Ethernet
Plug the 30W PoE+ Injector into any standard wall outlet. Plug one end of a Cat 5e or later ethernet cable into a cradlepoint / router or non PoE+ switch. Plug the other end of the cable into the Data In port located on the bottom of the Injector. Plug an additional ethernet cable into the Data & Power Out port also located on the bottom of the injector. Plug the other end of the ethernet cable into the sensor.
04 - Networking
Networking Basics
Density devices require internet connectivity to pass data to the web application.
Options to connect your Density devices to the internet:
• Option 1 - Wired internet via switch
• Option 2 - Wi-Fi (requires the Density Unit Setup App to locally set up the device)
• Option 3 - Wired internet via cradle-point
Networks that are not supported:
• Captive portal
• Proxy
• 5GHz Wifi networks
• WPA2 Enterprise
Hidden Networks (Hidden networks can be used if temporarily made transparent while we configure the devices.)
Network Configuration Options
Both DHCP and Static IP configurations are supported. (Static IP configurations require the Density Unit Setup App to locally set up the device).
DHCP Supported Configuration Options
Option 53 - DHCP Message Type
- Discover
Option 57 - Maximum DHCP Message Size
- 576
Option 55 - Parameter List
- Parameter request Line items
- Subnet Mask (1)
- Router (3)
- Interface MTU (26)
- Private/Proxy Auto Discovery (252)
- Network Time Protocol Servers (42)
- Domain Name (15)
- Domain Name Server (6)
- Hostname (12)
Option 60 - Vendor Class Identifier*
- "Density S5 DPU"
Option 61 - Client Identifier
- MAC Address
Option 12 - Hostname
- Density-<Serial>
Static Configuration Requirements
You will need an IPv4 Address and Name Servers from your IT team to use in the setup process. (Requires the Density Unit Setup App to locally set up the device).
If You Have a Corporate Firewall
You will need to whitelist the device MAC addresses (the MAC addresses can be found on the outside of the packaging box for the device). You may also have to whitelist the following addresses to ensure the device is able to communicate to your corporate network:
- *.density.io
- *.s3.amazonaws.com
- *.pool.ntp.org (required if using Static IP provisioning)
- connman.net
- connectivitycheck.gstatic.com
- 8.8.8.8 (if applicable)
- 8.8.4.4 (if applicable)
- a175u0txushx5b-ats.iot.us-west-2.amazonaws.com
Density does not currently support IP address whitelisting. A list of exact API subdomains is available by request.
Notes:
- The DPUs communicate via https, therefore port 443 must be open
- ntp port (port 123) must be open
- If internal DNS is not available then external dns servers 8.8.8.8 and 8.8.4.4 will be used and port 53 must be open
Unit Setup App
Used to configure units. iOS and Android application available - Go to mobile.density.io to download.
Temperature
The aluminum enclosure of the sensor is expected to be hot during operation. Density sensors are in compliance with certification temperature requirements and do not pose any risk of burning the skin or causing fires. If the sensor has been powered on for an extended period of time, it is recommended to remove the power cable and allow the sensor to cool for at least 5 minutes before handling.
Window Cleanliness
Smudges, fingerprints, and excessive dust can affect sensor’s ability to detect people. The sensor comes with a protective film that is designed to keep the window clean during the installation process. Remove the protective film after the installation is complete. Check the window for smudges or dust after the installation and wipe clean with a microfiber cloth if necessary. Make sure to check the sensor window every few months for excessive dust build up and wipe clean if necessary.
05 - Entryway Guidelines
Number of Sensors
To maintain an accurate count of a space, you need to install a sensor above every entryway to that space. The sensor is designed for indoor use only.
Field of View/Placement
The total detection area beneath the sensor is called the FOV (Field of View). To count people, the entryway needs adequate FOV coverage. Refer to the Install Height Chart to determine the minimum sensor height for your entryway.
The sensor should be centered horizontally above the entryway or hallway to ensure people are detected within the field of view. The exception to this rule is if the sensor height is at 100in (254cm) or below and the sensor is being mounted over a single swinging door. In this case, a sensor offset of 10in (25.4cm) will be needed. See Single Door Specifics Section.
The sensor cannot be mounted inside of the ceiling, on a side wall facing the entryway, or in the corner of a room.
Trigger Line
People are counted as they cross an invisible barrier known as the Trigger Line. The sensor needs to be installed as close to the entryway as possible to ensure people cross this line.
Install Height
The higher the sensor height, the greater the entryway FOV (Field of View) coverage. Install the sensor at its maximum height of 9ft 10in (118in or 300cm) for optimal entryway coverage. The minimum install height for the sensor is 7ft 8in (232cm). Refer to the Install Height Chart.
Sensor Height
Adequate sensor height is very important to ensure proper FOV coverage of the entryway. The Sensor Height is determined by measuring the distance between the front edge of the sensor or black window and the ground. The Wall Bracket Height is the distance between the bottom of the Wall Bracket and the ground. For wall mounted installations, Sensor Height can be determined by measuring the Wall Bracket Height and adding 2.5in (6.3cm) to that measurement.
Threshold Width
To determine the Threshold Width of the entryway, measure the open space that a person can physically walk through. Doors with handles can restrict the walkable pathway and reduce the FOV coverage requirements. For entryways with doors, open the door fully and measure the width of the unobstructed path through the doorway. For hallways or entryways with no doors, measure the distance from wall to wall.
Sensor Orientation
The sensor must be positioned parallel to the flow of traffic. If mounted near an entryway, the sensor should be pointing away from the wall.
Sensor Positioning
When mounting the sensor to the ceiling, make sure that the sensor is not mounted too close or too far away from the entryway/threshold. The optimal position for the threaded rod is 3.5in (8.9cm) away from the threshold/entryway.
In some cases obstructions or other environmental issues may call for the sensor to be installed outside of these guidelines. Any deviation from the guidelines should be under direct consultation of an account representative.
Exit Signs
Exit signs should be level with the front edge of the sensor or higher to avoid any light or FOV interference. If the exit sign is level with the front edge of the sensor, make sure that there is at least 12in (31cm) of space between the exit sign and the wall.
If an exit sign position falls outside these guidelines, reach out to your account representative or support@density.io to verify that there is no FOV or light interference.
Door Frames
Installing the sensor near a door frame can cause potential FOV interference. If your installation requires a door frame mount (section 9,10), make sure to position the sensor towards the front edge of the door frame.
Door Swing
The sensor performs best when mounted on the non-door swing side of the entryway.
Single Door Specifics
For some single doors, the optimal sensor placement is closer to the handle side of the door. Mount the sensor approximately 10in (25.4cm) away from the handle side of the door if your single door meets any of the below criteria:
• The sensor height is 100in (254cm) or less
• A door closer swings under the sensor
Black Tape
If the sensor is mounted too close to a swinging door, the IR light emitting from the sensor will bounce off of the top surface of the door and cause interference with the sensor. If the door swings underneath the sensor, and the distance between the sensor and the top of the door is 6in (15.2cm) or less, apply a strip of black painters or gaffers tape to the entire top surface of the door. Make sure to trim off any excess tape. The tape will help absorb the emitted sensor light, and mitigate any interference.
* Metal doors cause extreme light reflection at any sensor height. If your door is made of metal, apply a strip of black tape to the entire top surface of the door regardless of sensor height.
Door Swing Offset
Doors that swing both directions, and that are flush with the ceiling require the sensor to be ceiling mounted and offset away from the swinging door to avoid any collision. The maximum offset distance for the sensor is 12in (30.5cm), measured from the wall to the center of the sensor.
Overhang
Some doorways have a structural overhang which would prevent the sensor from being installed above the door at the optimal mounting height. The sensor can be offset from the door and mounted above the opening of the overhang. The opening will act as an extension of the door entryway. In order for the overhang mount to work, there needs to be structural side walls to confine human movement to the area beneath the sensor.
Install Height Chart - Single Sensor
To determine the necessary sensor height for a given threshold, first measure the threshold width (the physical opening that a person can walk through), then refer to the Install height Chart for the minimum sensor height. Use the minimum sensor height as the starting measurement for the Mounting Zone. The upper measurement of the mounting zone will be the overall maximum sensor install height of 118in (300cm). Mount the sensor near the center of the Mounting Zone.
* If the sensor height is at 100in (254cm) or below and the sensor is being mounted over a single swinging door, a sensor offset of 10in (25.4cm) will be needed. The sensor is offset to be positioned over the handle side of the door so coverage is emphasized on the side that people walk through the door. See Single Door Specifics.
If your entryway falls outside of these guidelines, additional sensors may be needed. Please reach out to your account representative or support@density.io
Clearance
For standard wall mount installations (section 5), a minimum of 6.75in (17.1cm) of unobstructed vertical wall space is required above the entryway. This allows enough clearance to mount the sensor, and for the sensor to receive adequate air flow to operate as expected.
For ceiling mount installations, the sensor cannot hang below the entryway if the door swings toward the sensor as the door will make contact. If the door swings toward the sensor, the sensor must be offset away from the door (see Door Swing Offset section).
Hallways
In certain scenarios the sensor can be suspended over hallways using a threaded rod and a Ceiling Mount Kit (section 8,9).
Make sure to follow the Install Height Chart for hallway installs.
Multiple Sensors
If entryway width is too wide, and the sensor cannot be mounted high enough for ample FOV coverage, an additional sensor or two can be added. We recommend using less sensors when possible, however, one entryway can support up to 3 sensors total.
When installing multiple sensors, they should be mounted in line and parallel to each other as shown.
Multi Unit Spacing - 2 Sensors
For 2 sensor installs, the distance between the centerpoint of the entryway and the center point of the left and right sensors should be equal (a = b). The distance from the ground to the sensors should also be equal (x = y).
Make sure to record distance between sensor centerpoints, sensor height, as well as both sensor serial numbers.
Install Height / Spacing Chart - 2 Sensors
The Install Height / Spacing Chart lists the minimum sensor height requirements for various threshold widths as well as the required distance between sensors.
To use the chart, measure the threshold width (the physical opening that a person can walk through), then look at the chart for the minimum required install height. Space the sensors over the threshold according to the Distance Between Sensors section of the chart. The minimum allowable distance between sensors is 22in (56cm), and the maximum allowable distance between sensors is 67in.
If needed, please reach out to your account representative or support@density.io for a walk through of the Install Height / Spacing Chart.
Multi Sensor Spacing - 3 Sensors
For 3 sensor installs, the distance between the centerpoint of centrally mounted sensor and the center point of the left and right sensors should be equal (a = b). The distance from the ground to the sensors should also be equal (x = y).
Make sure to record distance between sensor centerpoints, sensor height, as well as both sensor serial numbers.
Install Height / Spacing Chart - 3 Sensors
The Install Height / Spacing Chart lists the minimum sensor height requirements for various threshold widths as well as the required distance between sensors.
To use the chart, measure the threshold width (the physical opening that a person can walk through), then look at the chart for the minimum required install height. Space the sensors over the threshold according to the Distance Between Sensors section of the chart. The minimum allowable distance between sensors is 22in (56cm), and the maximum allowable distance between sensors is 67in.
06 - Mounting Options
Standard Wall Mount
For mounting the sensor to a variety of wall types using the provided multi-surface wall anchors and screws.
Refer to section 7 for more details and mounting instructions.
Ceiling Mount
For mounting the sensor to the ceiling in front of the entryway. Kit includes two options: A Toggle Anchor for hollow ceiling types like drywall or ceiling tiles as well as Threaded Rod and Expansion Anchors for a variety of solid surface materials like wood, metal, tile, stone & plaster.
Refer to section 8 and 9 for more details and mounting instructions.
Door Frame Mount (Top and Bottom)
For mounting the sensor to the top or bottom surface of a wood or metal door frame.
Refer to section 10 and 11 for more details and mounting instructions.
Glass/Metal Wall Mount
For mounting the sensor to a smooth glass or metal surface with semi-permanent adhesive.
Refer to section 12 for more details and mounting instructions.
07 - Wall Mounting
Wall Mount Kit (Included, available for order)
a. Wall Bracket
b. 2pcs #8 x 1.25in Rounded Head Screws
c. 2pcs Multi-Surface Anchors
d. Hex Key
Materials Not Included
Drill
Mallet or Hammer
Level
Measuring tape
Pencil
3/16in drill bit
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Mounting with Screws and Anchors
The Wall Mount Kit comes with 2pcs #8 x 1.25” Phillips Rounded Head Screws and 2pcs Multi-Surface Toggler Anchors designed for a wide range of materials (concrete, brick, stone, drywall, etc.). The anchor expands and elongates within a solid substrate to distribute force evenly. For hollow substrates, the anchor jaws pop open to lock into position.
Anchors should be used for all wall materials except for wood. For wood, use the screws and drill directly into the surface.
Cable Management - Hidden
For hollow wall installs, the cable can be hidden by drilling a hole into the wall material and threading the ethernet cable through thedrilled hole.
Cable Management - Exposed
For solid and hollow wall installs, the cable can be secured directly to the wall surface using cable clip fasteners or channeling.
Step 1: Prepare The Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to release the Wall Bracket from the Mount Arm.
Step 2: Mark Placement
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Center the Wall Bracket horizontally above the doorway. Use the level to ensure the Wall Bracket is parallel to the ground. Use a pencil to mark the center of the two holes in the Wall Bracket.
If there are any objects obstructing the sensor, you may install the sensor slightly off-center, or consider moving the obstruction. Please consult your Density Account Manager before offsetting the sensor.
Step 3: Drill Holes
Drill a hole through each pencil mark using a 3/16in drill bit. For hollow substrates, drill completely through. For solid wall materials, drill holes with a depth of at least 1 1/4in (3.2cm).
Step 4: Insert Anchors
Use a mallet or hammer to tap the anchors into each hole. Anchors should be flush with the wall.
Step 5: Install Wall Bracket
Align the holes in the Wall Bracket with the installed anchors. Use a drill with #2 Phillips Screwdriver Bit or manually with a standard Phillips head screwdriver to drive each screw into the drywall anchors.
Step 6: Power Up The Sensor
Plug in the ethernet cable. The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 7: Wall Mount
Slide the sensor downward onto the installed Wall Bracket.
Step 8: Lock Sensor and Peel Film
Lock the sensor to the Wall Bracket with the provided Hex Key by twisting the set screw all the way in. Remove the protective film on the black window.
Make sure the black sensor window remains free of dust and smudges during operation.
08 - Ceiling Mounting - Toggle Anchor
For Hollow Ceiling Types
Ceiling Mount Kit (available for order)
f. 1/4in-20 Toggle Anchor
g. Steel Washer
h. Hex Nut
d. Hex Key
Materials Not Included
Measuring tape
Drill
Wrench or Pliers
5/8in Drill Bit
1/4in-20 Threaded rod (5in minimum length)
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Toggle Anchor
Designed for hollow ceiling types (Drywall, Plaster, Ceiling Tile, Wood Paneling, etc.), the Toggle Anchor has spring loaded wings that fold flush, and then re-open once they have passed through the ceiling material.
Step 1: Prepare The Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to unscrew the two flat head screws and release the Mount Arm.
Step 2: Insert Rubber Plug
The sensor comes with a Rubber Plug (located in the Wall Mount Kit Box) designed to cosmetically cover the cavity where the Mount Arm was. Insert the plug by pressing the two pegs firmly into the two holes in the
Mount Cavity. A small arrow on the inner surface of the Rubber Plug indicates which direction should face upward.
Step 3: Drill Mounting Hole
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Mark a spot 3.5in (8.9cm) away from the wall that is centered horizontally above the entryway. Drill a hole all the way through the hollow ceiling material using the 5/8in drill bit.
Step 4: Assemble
Screw the sensor onto the bottom end of the threaded rod. Make sure that the threaded rod is screwed completely into the threads on the sensor. Screw the nut and washer onto the top end of the threaded rod. Screw the Toggle Anchor onto the top end of the threaded rod. Make sure that the threaded rod is fully threaded into the Toggle Anchor.
The 1/4”-20 threads on the sensor have an internal nylon washer which is designed to prevent the sensor from coming off the threaded rod. The nylon washer requires firm initial pressure to engage the threads of the rod. If needed, use a pair of pliers to clamp onto the threaded rod for a firm grip while threading on the sensor.
Step 5: Insert Toggle Anchor Into Ceiling
Fold the Toggle Anchor flaps down, then insert the Toggle Anchor and end of the threaded rod through the drilled hole. Once through the ceiling, the Toggle Anchor flaps will spring open again.
To adjust the install height, twist the threaded rod counter clockwise to raise or clockwise to lower (with a clearance of at least 3in between the top of the unit and the ceiling). Make sure the threaded rod has enough thread engagement with the Toggle Anchor.
Step 6: Tighten the Anchor Assembly
Once desired install height is determined (with a clearance of at least 3in between the top of the unit and the ceiling), twist the nut and washer until they are tight against the ceiling. Tighten the nut with a wrench or
pliers so that the washer provides strong clamping pressure against the ceiling.
Step 7: Power Up The Sensor
Plug in the ethernet cable. The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 8: Secure Cable
A zip tie can be used to secure the ethernet cable to the threaded rod for tidy cable management.
Step 9: Peel Film
Remove the protective film on the black window.
Make sure the black sensor window remains free of dust and smudges during operation.
Cable Management
A 1/2in PVC pipe can be used to run the cable and rod through. Before assembly, cut the PVC pipe to the proper length and drill or cut a notch or hole at the top of the pipe to allow for cable relief. For optimal cable
aesthetics, we recommend using a flat white Cat 5e or greater ethernet cable as shown. Make sure to use a pipe size with a minimum inner diameter of 0.62in (1.6cm).
Sensor Height
The illustration on the right indicates the distance from the ceiling to the internal sensor for each anchor type when the device is mounted as flush to the ceiling as possible. Note the minimum threaded rod length required.
09 - Ceiling Mounting - Threaded Anchor
For Solid Ceiling Types
Ceiling Mount Kit (available for order)
d. Hex Key
i. Threaded Rod Anchor - Wood
j. Threaded Rod Anchor - Steel
k. Expansions Anchor - Concrete
l. Installation Tool - Concrete
Materials Not Included in Kit
Measuring tape
Drill
5/8in Drive Socket - Wood only
1/2in Drive Socket - Steel only
ANSI 3/8” masonry bit - Concrete only
1/4in-20 Threaded rod (4in minimum for concrete,
3.25in minimum length for wood and steal)
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Threaded Rod Anchor
Install directly into a mounting surface to suspend a threaded rod. The Ceiling Mount Kit ships with three different mounting anchors designed for wood, steel, and concrete surfaces. The wood and steel anchors require a drill along with the appropriate sized drive socket (not included) for installation. The concrete anchor requires a hole drilled by an ANSI 3/8” masonry bit, as well as a hammer (not included) and an installation tool (included).
Step 1: Prepare The Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to unscrew the two flat head screws and release the Mount Arm.
Step 2: Insert Rubber Plug
The sensor comes with a Rubber Plug (located in the Wall Mount Kit Box) designed to cosmetically cover the cavity where the Mount Arm was. Insert the plug by pressing the two pegs firmly into the two holes in the Mount Cavity. A small arrow on the inner surface of the Rubber Plug indicates which direction should face upward.
Step 3: Install Ceiling Anchor
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Mark a spot 3.5in (8.9cm) away from the wall that is centered horizontally above the entryway.
Wood and Steel installation: Use a drill and a drive socket (5/8in for wood, 1/2in for steel) to drive the anchor into the ceiling until the bottom side of the anchor head is flush with the ceiling.
Concrete installation: Anchors for concrete require a hole drilled by an ANSI 3/8in masonry bit. To install, place the anchor into the drilled hole, insert the required installation tool into the anchor, and drive with a hammer until the thicker portion of the tool makes contact with the anchor. When installed, anchors sit flush with the surface.
Step 4: Assemble
Screw the sensor onto the bottom end of the threaded rod. Twist the threaded rod completely into the threads of the Anchor. Make sure that the threaded rod is threaded completely into both the sensor and the Anchor.
The 1/4”-20 threads on the sensor have an internal nylon washer which is designed to prevent the sensor from coming off the threaded rod. The nylon washer requires firm initial pressure to engage the threads of the rod.
Step 5: Power Up The Sensor
Plug in the ethernet cable. The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 6: Secure Cable
A zip tie can be used to secure the ethernet cable to the threaded rod for tidy cable management.
Step 7: Peel Film
Remove the protective film on the black window.
Make sure the black sensor window remains free of dust and smudges during operation.
Cable Management
A 1/2in PVC pipe can be used to run the cable and rod through. Before assembly, cut the PVC pipe to the proper length and drill or cut a notch or hole at the top of the pipe to allow for cable relief. For optimal cable
aesthetics, we recommend using a flat white Cat 5e or greater ethernet cable as shown. Make sure to use a pipe size with a minimum inner diameter of 0.62in (1.6cm).
Sensor Height
The illustrations on the right indicate the distance from the ceiling to the internal sensor when the device is mounted as close to the ceiling as possible, while remaining within our guidelines for optimal performance. Note the minimum threaded rod length required.
10 - Top of Frame Mounting
Door Frame Mount Kit (available for order)
m. Utility Mount
d. Hex Key
n. 2pcs Self-Drilling Screws, #6 x 1.5in
Materials Not Included in Kit
Drill
#2 Phillips Screwdriver Bit
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Cable Management
For tidier cable management, the ethernet cable can be run within the hollow frame.
Step 1: Screw In Utility Mount
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Center the Utility Mount horizontally above the entryway, and 1/4in (0.6 cm) away from the front edge of the frame as shown. Use a drill to drive both self-tapping screws through the Utility Mount and into the top of the door frame.
Step 2: Prepare The Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to release the Wall Bracket from the Mount Arm.
Step 3: Power Up The Sensor
Plug in the ethernet cable. The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 4: Mount the Sensor
Slide the sensor downward onto the Utility Mount.
Step 5: Lock Sensor and Peel Film
Lock the sensor to the Utility Mount with the provided hex key by twisting the set screw all the way in. Remove the protective film on the black window.
Make sure the black sensor window remains free of dust and smudges during operation.
11 - Bottom of Frame Mounting
Door Frame Mount Kit (available for order)
f. Utility Mount
d. Hex Key
k. 2pcs Self-Drilling Screws, #6 x 1.5in
Materials Not Included in Kit
Drill
#2 Phillips Screwdriver Bit
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Cable Management
For tidier cable management, the ethernet cable can be run within the hollow frame.
Step 1: Screw In the Door Frame Mount
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Center the Utility Mount horizontally above the entryway, and 0.27in (0.68cm) away from the front edge of the frame as shown. Use a drill to drive both self-tapping screws through the Utility Mount and into the bottom of the door frame.
Note the orientation of the Door Frame Mount.
Step 2: Prepare The Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to release the Wall Bracket from the Mount Arm.
Step 3: Power Up The Sensor
Plug in the ethernet cable. The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 4: Mount the Sensor
Slide the sensor downward onto the Utility Mount.
Step 5: Lock Sensor and Peel Film
Lock the sensor to the Utility Mount with the provided Hex Key by twisting the set screw all the way in. Remove the protective film on the black window.
Make sure the black sensor window remains free of dust and smudges during operation.
12 - Glass/Metal Adhesive Mounting
Glass/Metal Mount Kit (available for order)
o. Adhesive Mount
d. Hex Key
p. Hand Roller
q. 70% Isopropyl Alcohol (IPA) Wipe
Materials Not Included in Kit
Ethernet Cable (Cat 5e or later)
Power & Connectivity
All sensors require power over ethernet plus and internet connectivity.
Adhesive Mount Specs
The Adhesive Mount utilizes a 3M VHB adhesive specifically designed for glass and metal surfaces. The entire surface area of the adhesive must be in contact with the glass or metal surface it is adhered to.
Before installing, refer to and follow the supported mounting height and clearance requirements in section 5.
Step 1: Clean The Surface
Wipe the surfaces with the included isopropyl alcohol (IPA) wipe. Allow the surface to dry completely after wiping.
WARNING: THE ADHESIVE MOUNT IS DESIGNED FOR USE ON GLASS AND SMOOTH METAL SURFACES ONLY. DO NOT USE ON ANY OTHER SURFACE TYPES.
Step 2: Peel and Stick
Remove the protective lining on the back side of the mount. Adhere the mount onto the glass or metal surface, ensuring the mount is level with the ground.
Step 3: Attach to Wall Surface
Use the included hand roller to apply firm pressure across the front surface of the adhesive mount for at least 15 seconds.
WARNING: USE OF A HAND ROLLER IS REQUIRED TO ENSURE PROPER ADHESIVE BONDING AND TO PREVENT THE SENSOR FROM FALLING.
Step 4a: Wait For The Adhesive To Set
Before mounting the sensor, the adhesive on the mount must cure at room temperature for at least 24 hours. To accelerate the curing time, refer to step 4B below.
WARNING: THE ADHESIVE MOUNT MUST CURE FOR A MINIMUM OF 24 HOURS TO ENSURE PROPER ADHESIVE BONDING AND TO PREVENT THE SENSOR FROM FALLING.
Step 4b: Accelerated Adhesive Cure
To reduce the adhesive curing time to approximately 1 hour, use a heat gun and apply heat to the perimeter bonded surface of the adhesive mount for 1 minute. Next, apply heat to the entire front surface of the
adhesive mount for an additional minute. Allow the adhesive mount to rest at room temperature for 1 hour before mounting the sensor.
Step 5: Prepare the Sensor
Remove the protective film on the back of the sensor. Use the provided Hex Key to release the Wall Bracket from the Mount Arm.
Plug in a Cat5e or later ethernet cable (not included). The sensor will automatically power up and the LED indicator on the front of the sensor will turn white.
Step 6: Mount The Sensor
Align the bottom of the sensor mount arm approximately 1/8in (0.3cm) above the bottom edge of the adhesive mount. Move the sensor towards the adhesive mount (1). Slide the sensor downward (2), and then all
the way over to the right (3). The bottom of the sensor mount arm should be flush with the bottom of the adhesive mount when finished.
Step 7: Lock Sensor and Peel Film
Lock the sensor to the adhesive mount with the provided hex key by twisting the set screw all the way in. Remove the protective film on the black window. Make sure the black sensor window remains free of dust
and smudges during operation.
WARNING: THE SET SCREW MUST BE TIGHTENED ALL THE WAY TO PREVENT THE SENSOR FROM FALLING.